Description
Isolator Series UL60601-1 Listed Medical Grade Isolation Transformers offer line isolation, continuous noise filtering and enhanced common mode surge suppression. An internal low-impedance isolation transformer component offers 100% isolation from the input AC line. Full UL60601-1 medical-grade listing with hospital-grade plug and outlet receptacles makes Isolator medical-grade transformers ideal for protection of sensitive electronic equipment in patient-care areas. Faraday shield reduces the cumulative leakage current of the Isolator and connected equipment to levels less than 100 microamps. Secondary neutral-to-ground bonding virtually eliminates common mode noise, providing an isolated neutral-ground reference for sensitive equipment, and an inexpensive alternative to dedicated circuits and site electrical upgrades. Removes EMI/RFI noise, utility switching transients and harmonics generated by other on-site loads and utility or lightning related surge conditions. Active transformer filtering provides continuous common-mode noise rejection with no wearable parts. Unique ability to reduce surges in the worst of power environments to harmless levels. Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode. Model IS500HG includes 4 widely spaced NEMA 5-15R hospital-grade output receptacles, a 10-ft. power cord, hospital-grade input plug, circuit breaker overload protection, and lighted power switch. Rugged all-metal unit ships ready for placement in any industrial, medical, office or network environment. PLUG/OUTLETS: Input - NEMA 5-15P Hospital Grade; Output - 4 NEMA 5-15R Hospital Grade ELECTRICAL: 120V AC, 60Hz, 2.1A (Requires NEMA 5-15R wall receptacle) - The IS500HG Medical Grade Isolation Transformer offers line isolation and continuous noise filtering - Internal low-impedance isolation transformer with Faraday shield offers 100% isolation from the input AC line - Full UL60601-1 medical-grade listing with hospital-grade plug and outlet receptacles makes Isolator Hospital Grade transformers ideal for the protection of - sensitive electronic equipment in patient-care areas. - Reduces the cumulative leakage current of the Isolator and connected equipment to levels less than 100 microamps. - Secondary neutral-to-ground bonding eliminates common mode noise, providing an isolated ground reference for sensitive equipment - Serves as an inexpensive alternative to dedicated circuits and site electrical upgrades - Removes EMI/RFI noise, utility switching transients, load-generated harmonics and ground loops - Active transformer filtering offers continuous common-mode noise rejection with no wearable parts; unique ability to reduce surges in the worst of power - environments to harmless levels - Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode - Includes 4 widely spaced NEMA 5-15R hospital-grade output receptacles, a 10-ft. power cord, hospital-grade input plug, circuit breaker overload - protection and lighted power switch. - Rugged all-metal unit housing; ships ready for upright tower placement in any industrial, medical, office or network environment
Specification:
Features | |
---|---|
AC inlet type | C20 coupler |
AC outlet types | C13 |
AC outlets quantity | 6 AC outlet(s) |
AC input voltage | 115 - 230 V |
AC input frequency | 50 - 60 Hz |
Load capacity | 600 VA |
Input current (max) | 6 A |
Housing colour | White |
Certification | ANSI/AAMI ES60601-1:2005+A2+A1, IEC60601-1 3RD EDITION +A1, cAN/CSA-C22.2 NO. 60601-1:14, CE, NOM |
Short circuit protection | Yes |
Operational conditions | |
Operating temperature (T-T) | 0 - 40 °C |
Storage temperature (T-T) | -15 - 50 °C |
Operating relative humidity (H-H) | 5 - 95% |
Operating altitude | 0 - 118110.2" (0 - 3000 m) |
Weight & dimensions | |
Width | 7.87" (199.9 mm) |
Depth | 9.84" (249.9 mm) |
Height | 4.33" (110 mm) |
Weight | 20.4 lbs (9.24 kg) |
Package width | 12.8" (325.1 mm) |
Package depth | 14.6" (370.1 mm) |
Package height | 9.06" (230.1 mm) |
Package weight | 22.3 lbs (10.1 kg) |
Technical details | |
Products per master (outer) case | 1 pc(s) |
Master (outer) case width | 12.8" (325.1 mm) |
Master (outer) case gross weight | 22.3 lbs (10.1 kg) |
Master (outer) case length | 14.6" (370.1 mm) |
Master (outer) case height | 9.06" (230.1 mm) |
Logistics data | |
Country of origin | China |
Products per master (outer) case | 1 pc(s) |
Master (outer) case width | 12.8" (325.1 mm) |
Master (outer) case gross weight | 22.3 lbs (10.1 kg) |
Master (outer) case length | 14.6" (370.1 mm) |
Master (outer) case height | 9.06" (230.1 mm) |
Additional Information
Shipping & Return
Shipping Information
-
Delivery Time: 1-2 business days for order handling, with an additional 3-5 business days for transit within the USA.
-
Cost: Shipping is free for all products.
-
Tracking: You will receive a tracking number via email to monitor your order’s progress.
-
Support: For any shipping queries or issues, contact us at info@aeonfly.com or call +1 (302) 499-4044.
For full shipping details, please visit our complete shipping policy.
Reviews
My Wishlist
Wishlist is empty.
Compare
Shopping cart